Workshop & Manufacturing

Linear Assembly Tolerance Stack Calculator

Propagate signed dimensions through a one-dimensional assembly using worst-case and independent statistical conventions.

How the calculation works

Nominal assembly dimension = sum(dimensions) mm. Worst-case lower dimension = sum(dimensions)-sum(tolerances) mm. Worst-case upper dimension = sum(dimensions)+sum(tolerances) mm. Independent RSS half-width at same sigma multiplier = sqrt(sum_squares(tolerances)) mm. Assembly standard deviation = sqrt(sum_squares(tolerances))/sigma_factor mm.

Worked example

Example inputs — Signed nominal contributions (mm): 20 30 -10; Corresponding nonnegative symmetric half-tolerances (mm): 0.1 0.2 0.1; Each half-tolerance represents this many standard deviations: 3. Expected results — Nominal assembly dimension: 40 mm; Worst-case lower dimension: 39.6 mm; Worst-case upper dimension: 40.4 mm; Independent RSS half-width at same sigma multiplier: 0.2449489743 mm; Assembly standard deviation: 0.08164965809 mm.

Assumptions and limits

Linear additive stack only. Signs belong to nominal contributions, not tolerance magnitudes. RSS assumes independent centred random errors with the entered common sigma convention; it is not a guaranteed limit. Correlation and nonlinear geometry are excluded.

Reference and further reading

Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.

Related calculators

Browse all 1000 calculators →

Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.