Ideal Transformer Voltage & Current Calculator

Relate primary and secondary voltage/current through an ideal turns ratio.

How the calculation works

Secondary RMS voltage = primary_voltage*secondary_turns/primary_turns V. Primary load current = secondary_current*secondary_turns/primary_turns A. Transferred apparent power = primary_voltage*secondary_turns/primary_turns*secondary_current VA.

Worked example

Example inputs — Primary turns: 1000; Secondary turns: 100; Primary RMS voltage (V): 230; Secondary RMS load current (A): 2. Expected results — Secondary RMS voltage: 23 V; Primary load current: 0.2 A; Transferred apparent power: 46 VA.

Assumptions and limits

Idealized circuit arithmetic. Component ratings, tolerances, temperature, transients, isolation and electrical safety require independent checks; this tool does not certify a circuit. No winding loss, magnetizing current, regulation, saturation or frequency limitation. Does not infer isolation or safe transformer ratings.