How the calculation works
Total catchment area = area1+area2 ha. Area-weighted runoff coefficient = (area1*c1+area2*c2)/(area1+area2) . Weighted contributing area = area1*c1+area2*c2 ha. Estimated peak runoff = (area1*c1+area2*c2)*intensity/360 m³/s. Estimated peak runoff = (area1*c1+area2*c2)*intensity/360*1000 L/s.
Worked example
Example inputs — First contributing area (hectares): 1; First area runoff coefficient: 0.9; Second contributing area (hectares): 1; Second area runoff coefficient: 0.3; Rainfall intensity for concentration time (mm/hour): 50. Expected results — Total catchment area: 2 ha; Area-weighted runoff coefficient: 0.6; Weighted contributing area: 1.2 ha; Estimated peak runoff: 0.1666666667 m³/s; Estimated peak runoff: 166.6666667 L/s.
Assumptions and limits
Rational method Q=C i A for an idealized small catchment. The entered intensity must correspond to the relevant storm duration/time of concentration and local design criteria; no rainfall-frequency lookup is supplied. Assumes uniform rainfall and constant coefficients. It estimates peak rate, not storm volume or a hydrograph, and ignores routing, detention and spatial variation. Results are not drainage-system design approval.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Growing Degree-Day Series & Target Calculator
- Hourly Chill Accumulation & Requirement Calculator
- Daily Root-Zone Water Balance & Depletion Trigger Calculator
- Sprinkler Catch-Can Uniformity & Application Rate Calculator
- Grain Wet/Dry Moisture & Drying Shrink Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.