Sound & Audio
Room Schroeder Frequency & Critical Distance Calculator
Estimate two room-acoustic scales from volume, reverberation time and source directivity.
How the calculation works
Approximate Schroeder transition = 2000*sqrt(reverb/volume) Hz. Approximate direct/reverberant critical distance = 0.057*sqrt(directivity*volume/reverb) m.
Worked example
Example inputs — Room volume (m³): 100; Reverberation time T60 (s): 1; Source directivity factor Q: 2. Expected results — Approximate Schroeder transition: 200 Hz; Approximate direct/reverberant critical distance: 0.8061017306 m.
Assumptions and limits
Idealized acoustic/audio arithmetic with matching RMS, frequency and reference conventions. Real rooms, transducers and devices need measurement; this result is not a hearing-exposure or building-compliance assessment. Empirical diffuse-field approximations. Critical distance is not microphone placement advice for every room, and the transition is not a sharp boundary between two exact regimes.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Sound Pressure, Intensity & Particle Velocity Calculator
- Multiple Incoherent Sound Level Calculator
- Background Sound Level Subtraction Calculator
- Free-Field Sound Level versus Distance Calculator
- Sabine & Eyring Room Reverberation Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.