Sound & Audio
Sabine & Eyring Room Reverberation Calculator
Compare diffuse-field reverberation estimates and the absorption needed for a selected target decay time.
How the calculation works
Equivalent absorption area = surface*absorption m² sabins. Sabine reverberation time = 0.161*volume/(surface*absorption) s. Eyring reverberation time = -0.161*volume/(surface*log(1-absorption)) s. Sabine absorption area for target = 0.161*volume/target m² sabins.
Worked example
Example inputs — Room volume (m³): 100; Total room boundary area (m²): 150; Area-weighted mean absorption coefficient: 0.2; Desired reference reverberation time (s): 0.5. Expected results — Equivalent absorption area: 30 m² sabins; Sabine reverberation time: 0.5366666667 s; Eyring reverberation time: 0.4810057593 s; Sabine absorption area for target: 32.2 m² sabins.
Assumptions and limits
Idealized acoustic/audio arithmetic with matching RMS, frequency and reference conventions. Real rooms, transducers and devices need measurement; this result is not a hearing-exposure or building-compliance assessment. Diffuse sound field, frequency-specific average absorption, no explicit air absorption and the SI 0.161 coefficient. Nonuniform treatment and small-room modes can invalidate either estimate.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Sound Pressure, Intensity & Particle Velocity Calculator
- Multiple Incoherent Sound Level Calculator
- Background Sound Level Subtraction Calculator
- Free-Field Sound Level versus Distance Calculator
- Rectangular Room Acoustic Mode Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.