Equivalent absorption area = surface*absorption m² sabins. Sabine reverberation time = 0.161*volume/(surface*absorption) s. Eyring reverberation time = -0.161*volume/(surface*log(1-absorption)) s. Sabine absorption area for target = 0.161*volume/target m² sabins.

Worked example

Example inputs — Room volume (m³): 100; Total room boundary area (m²): 150; Area-weighted mean absorption coefficient: 0.2; Desired reference reverberation time (s): 0.5. Expected results — Equivalent absorption area: 30 m² sabins; Sabine reverberation time: 0.5366666667 s; Eyring reverberation time: 0.4810057593 s; Sabine absorption area for target: 32.2 m² sabins.

Assumptions and limits

Idealized acoustic/audio arithmetic with matching RMS, frequency and reference conventions. Real rooms, transducers and devices need measurement; this result is not a hearing-exposure or building-compliance assessment. Diffuse sound field, frequency-specific average absorption, no explicit air absorption and the SI 0.161 coefficient. Nonuniform treatment and small-room modes can invalidate either estimate.