Sound & Audio
Free-Field Sound Level versus Distance Calculator
Predict a level change from one measured source distance to another under spherical spreading.
How the calculation works
Modelled target sound level = reference_level-20*log10(target_distance/reference_distance)-air_loss*(target_distance-reference_distance) dB. Geometric spreading change = -20*log10(target_distance/reference_distance) dB.
Worked example
Example inputs — Measured reference level (dB): 90; Reference distance from source (m): 1; Target distance (m): 10; Additional atmospheric loss rate (dB/m): 0. Expected results — Modelled target sound level: 70 dB; Geometric spreading change: -20 dB.
Assumptions and limits
Idealized acoustic/audio arithmetic with matching RMS, frequency and reference conventions. Real rooms, transducers and devices need measurement; this result is not a hearing-exposure or building-compliance assessment. Point-like source, same direction and unobstructed far field. Reflections, ground effects, barriers, wind and frequency-dependent absorption are not resolved.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Sound Pressure, Intensity & Particle Velocity Calculator
- Multiple Incoherent Sound Level Calculator
- Background Sound Level Subtraction Calculator
- Sabine & Eyring Room Reverberation Calculator
- Rectangular Room Acoustic Mode Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.