Sound & Audio

Two-Path Delay Comb Filter Calculator

Locate ideal comb-filter cancellation and repetition spacing for two equal same-polarity paths.

How the calculation works

First destructive interference frequency = 1/(2*delay_ms*.001) Hz. Spacing between successive notches = 1/(delay_ms*.001) Hz. Second destructive frequency = 3/(2*delay_ms*.001) Hz.

Worked example

Example inputs — Time difference between equal coherent paths (ms): 1. Expected results — First destructive interference frequency: 500 Hz; Spacing between successive notches: 1000 Hz; Second destructive frequency: 1500 Hz.

Assumptions and limits

Idealized acoustic/audio arithmetic with matching RMS, frequency and reference conventions. Real rooms, transducers and devices need measurement; this result is not a hearing-exposure or building-compliance assessment. Equal amplitudes, same polarity and constant delay. Unequal amplitudes leave residual notches; a polarity reversal swaps the peak/notch sequence.

Reference and further reading

Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.

Related calculators

Browse all 1000 calculators →

Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.