Sound & Audio
Two-Path Delay Comb Filter Calculator
Locate ideal comb-filter cancellation and repetition spacing for two equal same-polarity paths.
How the calculation works
First destructive interference frequency = 1/(2*delay_ms*.001) Hz. Spacing between successive notches = 1/(delay_ms*.001) Hz. Second destructive frequency = 3/(2*delay_ms*.001) Hz.
Worked example
Example inputs — Time difference between equal coherent paths (ms): 1. Expected results — First destructive interference frequency: 500 Hz; Spacing between successive notches: 1000 Hz; Second destructive frequency: 1500 Hz.
Assumptions and limits
Idealized acoustic/audio arithmetic with matching RMS, frequency and reference conventions. Real rooms, transducers and devices need measurement; this result is not a hearing-exposure or building-compliance assessment. Equal amplitudes, same polarity and constant delay. Unequal amplitudes leave residual notches; a polarity reversal swaps the peak/notch sequence.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Sound Pressure, Intensity & Particle Velocity Calculator
- Multiple Incoherent Sound Level Calculator
- Background Sound Level Subtraction Calculator
- Free-Field Sound Level versus Distance Calculator
- Sabine & Eyring Room Reverberation Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.