Sound & Audio
Audio Crest Factor & Amplifier Headroom Calculator
Relate average load power, signal crest factor and peak voltage under a resistive-load model.
How the calculation works
RMS output voltage = sqrt(average_power*resistance) V. Peak output voltage = sqrt(average_power*resistance)*10**(crest_db/20) V. Peak instantaneous load power = average_power*10**(crest_db/10) W.
Worked example
Example inputs — Average electrical load power (W): 10; Resistive load (ohms): 8; Voltage crest factor (dB): 6.020599913279624. Expected results — RMS output voltage: 8.94427191 V; Peak output voltage: 17.88854382 V; Peak instantaneous load power: 40 W.
Assumptions and limits
Idealized acoustic/audio arithmetic with matching RMS, frequency and reference conventions. Real rooms, transducers and devices need measurement; this result is not a hearing-exposure or building-compliance assessment. Crest factor is peak/RMS voltage. Peak instantaneous power is not the same as an amplifier’s continuous sine rating; reactive speaker impedance and clipping are excluded.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Sound Pressure, Intensity & Particle Velocity Calculator
- Multiple Incoherent Sound Level Calculator
- Background Sound Level Subtraction Calculator
- Free-Field Sound Level versus Distance Calculator
- Sabine & Eyring Room Reverberation Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.