Heat & Thermodynamics

Combined Convection & Radiation Cooling Calculator

Build a surface heat-loss budget that separates convection and radiation at the same operating temperature.

How the calculation works

Convective heat loss = area*coefficient*(surface-ambient) W. Radiative heat loss = area*emissivity*5.670374419e-8*(surface**4-ambient**4) W. Combined heat loss = area*(coefficient*(surface-ambient)+emissivity*5.670374419e-8*(surface**4-ambient**4)) W.

Worked example

Example inputs — Exposed area (m²): 1; Convection coefficient (W/m²/K): 10; Emissivity: 0.8; Surface temperature (K): 400; Air and large surroundings temperature (K): 300. Expected results — Convective heat loss: 1000 W; Radiative heat loss: 793.8524187 W; Combined heat loss: 1793.852419 W.

Assumptions and limits

Idealized thermal model using the supplied material properties. Values depend on actual temperatures and conditions; no equipment rating, burn protection or building compliance is established. Same ambient temperature for air and large radiative surroundings, steady uniform surface and no conduction path. This budget does not solve transient temperature or a safe-touch limit.

Reference and further reading

Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.

Related calculators

Browse all 1000 calculators →

Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.