Heat & Thermodynamics
Biot & Fourier Number Calculator
Compare internal and surface thermal resistance and nondimensional elapsed conduction time.
How the calculation works
Biot number hL/k = coefficient*length/conductivity dimensionless. Fourier number alpha t/L² = diffusivity*time/length**2 dimensionless.
Worked example
Example inputs — Convection coefficient h (W/m²/K): 10; Chosen characteristic length L (m): 0.01; Conductivity k (W/m/K): 1; Thermal diffusivity alpha (m²/s): 1e-06; Elapsed time (s): 100. Expected results — Biot number hL/k: 0.1 dimensionless; Fourier number alpha t/L²: 1 dimensionless.
Assumptions and limits
Idealized thermal model using the supplied material properties. Values depend on actual temperatures and conditions; no equipment rating, burn protection or building compliance is established. The characteristic length must follow the convention of the thermal solution being used. Dimensionless numbers alone do not prove model adequacy or determine a temperature profile.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Isotropic Solid Thermal Expansion Calculator
- Fully Restrained Thermal Stress Calculator
- Thermal Expansion Liquid Overflow Calculator
- Two-Body Mixing Equilibrium Temperature Calculator
- Latent Heat Phase Change Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.