Optics & Imaging
Optical Pulse Energy & Peak Power Calculator
Relate average optical power, pulse repetition rate and a rectangular-equivalent pulse duration.
How the calculation works
Energy per pulse = average_power/repetition*1000 mJ. Rectangular-equivalent peak power = average_power/(repetition*duration*1e-9) W. Pulse duty fraction = repetition*duration*1e-9 fraction.
Worked example
Example inputs — Average optical power (W): 10; Pulse repetition frequency (Hz): 1000; Rectangular-equivalent pulse duration (ns): 10. Expected results — Energy per pulse: 10 mJ; Rectangular-equivalent peak power: 1000000 W; Pulse duty fraction: 1e-05 fraction.
Assumptions and limits
Idealized optical model with the stated units and sign convention. Real components have dispersion, aberrations, tolerances and alignment limits; no laser or eye-safety rating is inferred. Pulse shape changes the relation between FWHM duration and true peak power. No beam size, exposure hazard or safe operating limit is evaluated.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Snell Refraction Angle Calculator
- Total Internal Reflection Critical Angle Calculator
- Fresnel Interface Reflectance Calculator
- Brewster Polarization Angle Calculator
- Thin Lens Image Distance & Magnification Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.