Fluids & Hydraulics

Ideal Venturi Meter Flow Calculator

Infer incompressible flow from a Venturi pressure difference and two internal diameters.

How the calculation works

Volume flow = coefficient*pi*throat**2/4*sqrt(2*delta_p/(density*(1-(throat/inlet)**4)))*1000 L/s.

Worked example

Example inputs — Upstream diameter (m): 0.1; Throat diameter (m): 0.05; Upstream minus throat pressure (Pa): 7500; Fluid density (kg/m³): 1000; Discharge coefficient: 1. Expected results — Volume flow: 7.853981634 L/s.

Assumptions and limits

Simplified fluid model with SI inputs. Results are not a pressure-vessel, piping-code, flood-control or safety certification. Equal-elevation pressure taps and incompressible flow. The selected discharge coefficient must suit the meter; gas expansion and metering standards are not included.

Reference and further reading

Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.

Related calculators

Browse all 1000 calculators →

Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.