Fluids & Hydraulics
Tank Outlet Speed & Orifice Flow Calculator
Estimate gravity-driven exit speed and discharge through a small outlet beneath a water surface.
How the calculation works
Ideal exit speed = sqrt(2*gravity*head) m/s. Estimated discharge = coefficient*pi*(diameter/1000)**2/4*sqrt(2*gravity*head)*1000 L/s.
Worked example
Example inputs — Free-surface height above outlet (m): 5; Outlet diameter (mm): 20; Discharge coefficient: 0.5; Gravity (m/s²): 10. Expected results — Ideal exit speed: 10 m/s; Estimated discharge: 1.570796327 L/s.
Assumptions and limits
Simplified fluid model with SI inputs. Results are not a pressure-vessel, piping-code, flood-control or safety certification. Large open tank and small outlet, negligible free-surface speed and equal atmospheric pressures. Head falls during draining unless maintained; the coefficient is user-selected.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Fluid Density & Specific Weight Calculator
- Hydrostatic Gauge & Absolute Pressure Calculator
- Differential Manometer Pressure Calculator
- Ideal Hydraulic Press Force & Stroke Calculator
- Buoyant Force & Apparent Weight Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.