Fluids & Hydraulics

Fitting K-Factor Pressure Loss Calculator

Estimate combined local head and pressure losses from a sum of fitting loss coefficients.

How the calculation works

Local pressure loss = sum_k*density*velocity**2/2 Pa. Local head loss = sum_k*velocity**2/(2*gravity) m.

Worked example

Example inputs — Sum of loss coefficients K: 3; Reference mean velocity (m/s): 2; Fluid density (kg/m³): 1000; Gravity (m/s²): 10. Expected results — Local pressure loss: 6000 Pa; Local head loss: 0.6 m.

Assumptions and limits

Simplified fluid model with SI inputs. Results are not a pressure-vessel, piping-code, flood-control or safety certification. All K values must use a consistent reference velocity and matching flow direction. Straight-pipe friction is separate.

Reference and further reading

Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.

Related calculators

Browse all 1000 calculators →

Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.