Fluids & Hydraulics
Manning Rectangular Channel Flow Calculator
Estimate uniform open-channel flow from rectangular section, slope and a selected Manning roughness.
How the calculation works
Mean velocity = (width*depth/(width+2*depth))**(2/3)*sqrt(slope)/roughness m/s. Discharge = width*depth*(width*depth/(width+2*depth))**(2/3)*sqrt(slope)/roughness m³/s.
Worked example
Example inputs — Channel width (m): 2; Water depth (m): 0.5; Energy slope (m/m): 0.0009; Manning n (SI convention): 0.03. Expected results — Mean velocity: 0.4807498568 m/s; Discharge: 0.4807498568 m³/s.
Assumptions and limits
Simplified fluid model with SI inputs. Results are not a pressure-vessel, piping-code, flood-control or safety certification. Steady uniform flow using the SI Manning equation. Roughness and energy slope must be appropriate; backwater, transitions and critical-flow controls are excluded.
Reference and further reading
Read the underlying subject reference. Calculith is an independent implementation; the reference does not endorse or certify this tool.
Related calculators
- Fluid Density & Specific Weight Calculator
- Hydrostatic Gauge & Absolute Pressure Calculator
- Differential Manometer Pressure Calculator
- Ideal Hydraulic Press Force & Stroke Calculator
- Buoyant Force & Apparent Weight Calculator
Example values are editable. Results are estimates where assumptions apply. Calculations run in your browser. Updated 2026-11-16.