CIELAB ΔE76 & CIEDE2000 Color Difference Calculator

Compare two measured CIELAB triples using Euclidean ΔE76 and the CIEDE2000 weighting and hue-interaction model.

How the calculation works

ΔE76 is Euclidean distance in Lab. CIEDE2000 adjusts a*, calculates primed chroma/hue differences, applies SL, SC, SH and parametric factors, then includes the RT chroma–hue interaction term; hue wrap and zero-chroma cases are handled explicitly.

Worked example

Example inputs — First L*, a*, b* triple: 50, 2.6772, -79.7751; Second L*, a*, b* triple: 50, 0, -82.7485; Lightness parametric factor kL: 1; Chroma parametric factor kC: 1; Hue parametric factor kH: 1. Expected results — Euclidean ΔE76: 4.001063284; CIEDE2000 ΔE00: 2.04245968.

Assumptions and limits

Mathematical color model with stated reference conventions; device calibration, viewing conditions and color-management profiles affect practical appearance. Both triples must use the same reference white, observer and measurement conditions. L* must be 0–100; a*, b* are signed. kL,kC,kH default to reference factors of one. No universal visible-difference or acceptance threshold is implied. Reference example is the first Sharma–Wu–Dalal test pair.